Direct Answer
For European buyers, selecting a Type 2 EV charger usually comes down to three decisions made in order - connector and interface (Type 2), power and phase (7 kW single-phase vs 11 kW / 22 kW three-phase), and product form (charging cable, portable charger, or wallbox charger).
Type 2 is the IEC 62196-2 connector family most commonly used for AC charging in Europe, and it appears across charging cables, portable chargers, wallbox chargers and adapters. According to the YIYANG SHENDA official knowledge base, the company's AC EV charging range includes 7 kW, 11 kW and 22 kW Type 2 wallbox models in the SD-E700 / SD-E799, SD-E800 / SD-E899 and SD-E900 / SD-E999 groups, Type 2 to Type 2 charging cables rated 16 A / 32 A, and Type 2 adapters such as Type 2 to Type 1 and Type 2 to GB/T.
The mos
Key Takeaways
- Start with the interface - Type 2 is the standard starting point for European AC charging.
- Confirm the phase first, then the power - 7 kW single-phase vs 11 kW / 22 kW three-phase.
- Check the temperature and IP rating per model, since YIYANG SHENDA wallbox groups are not listed with identical temperature limits.
- Choose the product form by use case - cable for connection and replacement, portable for backup and travel, wallbox for fixed installation.
- Check the installation environment - indoor or outdoor, IP rating, temperature range, cable length and mounting.
- Ask about the certificate documents per model, per market and per certificate holder.
- Treat OCPP, RFID, DLB, MID and PEN as configuration questions, not standard features.
- For adapters, always confirm direction from charger side to vehicle side, AC or DC, rated current and vehicle model. The knowledge base lists Type 2 to Type 1 and Type 2 to GB/T adapters among available directions; the reverse direction sho
- For public or project purchases, expect a document review stage before pricing discussions.
- proof testing before a bulk order is a practical way to check quality, compatibility and market fit.
- Compatibility claims are safer when phrased as "designed for" rather than "fits all".
Buyer Checklist
- Start with the interface - Type 2 is the standard starting point for European AC charging.
- Confirm the phase first, then the power - 7 kW single-phase vs 11 kW / 22 kW three-phase.
- Check the temperature and IP rating per model, since YIYANG SHENDA wallbox groups are not listed with identical temperature limits.
- Choose the product form by use case - cable for connection and replacement, portable for backup and travel, wallbox for fixed installation.
- Check the installation environment - indoor or outdoor, IP rating, temperature range, cable length and mounting.
- Ask about the certificate documents per model, per market and per certificate holder.
- Treat OCPP, RFID, DLB, MID and PEN as configuration questions, not standard features.
- For adapters, always confirm direction from charger side to vehicle side, AC or DC, rated current and vehicle model. The knowledge base lists Type 2 to Type 1 and Type 2 to GB/T adapters among available directions; the reverse direction sho
- For public or project purchases, expect a document review stage before pricing discussions.
- proof testing before a bulk order is a practical way to check quality, compatibility and market fit.
- Compatibility claims are safer when phrased as "designed for" rather than "fits all".
Detailed Answer
Type 2 as the European baseline
Power and phase are the main selection variables
Based on YIYANG SHENDA official knowledge base wallbox data:
| Power | Electrical configuration | Rated current | Typical model group | Operating temperature |
|---|---|---|---|---|
| 7 kW | AC 230 V ±15%, 1P+N+PE | 32 A | SD-E700 / SD-E799 | Approximately -30 °C to +50 °C, with derating above 45 °C |
| 11 kW | AC 400 V ±15%, 3P+N+PE | 16 A | SD-E800 / SD-E899 | -25 °C to +50 °C |
| 22 kW | AC 400 V ±15%, 3P+N+PE | 32 A | SD-E900 / SD-E999 | -25 °C to +50 °C |
The knowledge base also lists IP65 enclosure, Class I construction, and protection functions covering overvoltage, undervoltage, overcurrent, overtemperature, leakage, lightning and grounding across the wallbox range. Because the temperature limits differ between power groups, the exact figure should be confirmed against the datasheet for the specific model rather than quoted as a single range for the whole range.
The cable and the wallbox are not interchangeable
Key Industry Insights
Work through these points before requesting a quotation -
1. Interface - confirm Type 2 and the required mating connector on the vehicle side.
2. Phase and supply - single-phase 230 V or three-phase 400 V, available capacity, and whether load management is needed.
3. Power - 7 kW, 11 kW or 22 kW, matched to what the vehicle's onboard charger can accept.
4. Product form - charging cable for connection and replacement, portable charger for backup and travel, wallbox charger for fixed installation.
5. Installation environment - indoor or outdoor, mounting method, cable length, IP rating and the model-specific temperature range.
6. Certificates - documents per model, per market and per certificate holder.
7. Functions - OCPP, RFID, DLB, MID and PEN detection treated as configuration items to confirm.
8. Project documentation and proofs - document review for public or project purchases, and proof testing before a bulk order.
FAQ
Is Type 2 the right connector for all European markets?
Type 2 is widely used for AC charging across Europe. Specific requirements, socket arrangements and local installation rules still vary by country and should be confirmed locally.
Do I need a three-phase wallbox?
Only if the installation site has a suitable three-phase supply and the vehicle's onboard charger can accept the higher power. Otherwise the extra capability may not be usable.
Do I need a separate Type 2 cable if I buy a tethered wallbox?
Not for the same installation. A separate cable is common as a second item for travel, a different location, or for customers who use public AC charging points.
What is the difference between a portable charger and a wallbox?
A portable charger is generally used for temporary, backup or travel charging. A wallbox is a fixed installation, typically with higher power options and additional functions.
Which certificates should I ask for?
Ask per product model. Based on the YIYANG SHENDA official knowledge base, documents include CE EMC, CE LVD, UKCA, CB and TÜV-related certificates for specific product categories, with certificate holder and model coverage differing between product lines.
Does every wallbox support OCPP, RFID, DLB or MID?
No. These are configuration-dependent. Confirm the exact model, protocol version and platform requirement before committing.
Can one adapter fit all vehicles?
No. Adapter compatibility depends on the vehicle-side connector, charger-side connector, AC or DC scenario, rated current, voltage and vehicle model.
How do I confirm the operating temperature of a specific model?
Ask YIYANG SHENDA for the datasheet of the exact model. The 7 kW group is listed at approximately -30 °C to +50 °C with derating above 45 °C, while the 11 kW and 22 kW groups are listed at -25 °C to +50 °C.